SWP02426RS.FITS Headers
Primary Header SIMPLE = T / file does conform to FITS standard BITPIX = 8 / number of bits per data pixel NAXIS = 0 / number of data axes EXTEND = T / FITS dataset may contain extensions TELESCOP= 'IUE ' / International Ultraviolet Explorer DATE = '14/05/97' / Date file written ORIGIN = 'GSFC ' / Institution generating the file CAMERA = 'SWP ' / Camera IMAGE = 2426 / Sequential image number DISPERSN= 'HIGH@LOW' / Dispersion processing type APERTURE= 'SMALL ' / Aperture ABNNOSTD= 'NO ' / Non-standard image acquisition ABNBADSC= 'NO ' / LWP bad scans ABNHTRWU= 'NO ' / LWR heater warmup ABNREAD = 'NO ' / Read at other than 20 KB ABNUVC = 'NO ' / Non-standard UVC voltage ABNHISTR= 'NO ' / History replay ABNOTHER= 'NO ' / Other abnormality POSANGLE= 25.86 / Pos angle of the large aperture (deg) ABNMINFR= 'NO ' / Bad/missing minor frames CC-PERCN= 95.0 / Cross-correlation % successful ITF = 'SWP85R92A' / ITF identification COMMENT BY RA: COMMENT BY GO: DATEOBS = '31/08/78' / Observing date TIMEOBS = '20:39:14' / Observing time EXPTRMD = 'NO-TRAIL' / Trail mode EXPMULT = 'NO ' / Multiple exposure mode EXPSEGM = 'NO ' / Segmented exposure code EXPTIME = 3599.844 / Integration time in seconds RA = 298.8333 / Homogeneous R.A. in degrees DEC = 39.6950 / Homogeneous Dec. in degrees TARGET = 'V1016CYG' / Object as given by Guest Observer TARGRA = 298.8250 / R.A. in degrees (given by GO) TARGDEC = 39.6900 / Dec. in degrees (given by GO) OBJECT = 'V* V1016 CYG' / Homogeneous Object ID HJD-MID = 2443752.38421 / JD middle of obs. with Heliocentric corr. RADVELO = -3.54 / Heliocentric velocity correction in km/s COMMENT IUE-VICAR HEADER START NO LAMP-EXP TIME=3599 SECS V 1016 CYGN 60M,0S, SWP 2426, HI RESS S AP, SPREP, MAXG, LO READ 20:39:14, 31 AUG 78, FLOWER COMMENT IUE-VICAR HEADER END HISTORY START RAW_SCREEN 14-MAY-1997 13:22:56 HISTORY 23 BRIGHT SPOTS DETECTED HISTORY 0 MISSING MINOR FRAMES DETECTED HISTORY SMALL APERTURE CONTINUUM DN LEVEL = 61 HISTORY BACKGROUND DN LEVEL = 27 HISTORY ORDER REGISTRATION HISTORY INSUFFICIENT FLUX FOR EMPIRICAL ORDER REGISTRATION HISTORY RMS OF FOUND VS ACTUAL ORDER POSITIONS > NOISE CRITERION HISTORY PREDICTIONS BASED ON TIME AND TEMPERATURE WILL BE USED HISTORY END RAW_SCREEN 14-MAY-1997 13:22:59 END Binary Table Header XTENSION= 'BINTABLE' /Written by IDL: 2-Feb-1998 08:48:08.00 BITPIX = 8 / NAXIS = 2 /Binary table NAXIS1 = 14 /Number of bytes per row NAXIS2 = 495 /Number of rows PCOUNT = 0 /Random parameter count GCOUNT = 1 /Group count TFIELDS = 4 /Number of columns TFORM1 = '1E ' /Real*4 (floating point) TTYPE1 = 'WAVELENGTH' /Label for column 1 TUNIT1 = 'ANGSTROM' /Units of column 1 TDISP1 = 'F10.3 ' /Display format for column 1 TFORM2 = '1E ' /Real*4 (floating point) TTYPE2 = 'FLUX ' /Label for column 2 TUNIT2 = 'ERG/CM2/S/A' /Units of column 2 TDISP2 = 'E15.7 ' /Display format for column 2 TFORM3 = '1E ' /Real*4 (floating point) TTYPE3 = 'SIGMA ' /Label for column 3 TUNIT3 = 'ERG/CM2/S/A' /Units of column 3 TDISP3 = 'E15.7 ' /Display format for column 3 TFORM4 = '1I ' /Integer*2 (short integer) TTYPE4 = 'QUALITY ' /Label for column 4 TUNIT4 = ' ' /Units of column 4 TDISP4 = 'I7 ' /Display format for column 4 FILENAME= 'SWP02426RS.FITS' /Filename(camera)(number)(disp)(aper).FITS END